-40%
12/24v Conversion icebox to fridge with 20x10" plate *No gas No Wiring* R134A
$ 242.87
- Description
- Size Guide
Description
KINGETC Brand Icebox conversion kitmodel COQD
35-2010
This is a Conversion kit Icebox to fridge for up to
6.25 cuft (180L) and
freezer 2.1
cuft
(60L).
Low amperage draw! Made in Canada
There no gas included or precharged. Professional installation recommended.
No wiring included. Marine grade Ready-made wiring harness soon available.
=====
Specification :
12-24Vdc compressor Model QDZH35G (equivalent to bd35f) CE certified
compact condensing air-cooled unit 9"x11"x7"
Electronic thermostat included with 2m probe(not shown)
6 foot of conduit from unit to plate
10"x20" evaporator plate with spacers
insulation and tape included
=====
Notes:
Wiring : 1/4 quick terminals and crimper required
10 gauge and a 15 amps for 12v (7.5amps for 24v) fuse for power input, 18 gauge wire for the rest.
Here simplified installation instructions
=====
Gas not precharged, Refrigeration knowledge and tools required.
Installation Procedure is
similar
to a mini-split.
Screw condensing unit in a vented area and Evaporator in icebox with spacers(leave a space between evap and wall)
Route Evaportator piping to condensing unit and tighten flare
fittings, Secure with clamps and insulate copper pipe.
Tighthen fittings with 2 wrench, only the nut have to turn. avoid to twist the pipe
Pressure check system for leaks with nitrogen at 50psi (higher will deform evaporator)
Follow wiring
schematic
to connect compressor, fan and thermostat
Pull vaccum for about down to at least 500 micron (vacuuming time not significant, proper gauge needed)
Fill around 4 oz of R134a refrigerant into the well vacuumed system, Leave Manifold and Refrigerant bottle attached to system to add refrigerant later.
Start compressor, let system run for 5-10 mins , check pressures (Manifold gauges) and temperatures (Infrared thermometer) during that time.
If ,On the Low pressure side, Pressure fall under 0-3 psi when compressor running , add more refrigerant.
Refer to R-134A Temp-pressure chart to make sure you get superheat and subcooling, that will ensure proper refrigerant charge.
Stop compressor, Remove Manifold and Put Back both access valve caps.
=====
I always carefully pack items with care to avoid damage during shipping.