-40%

12/24v Conversion icebox to fridge with 20x10" plate *No gas No Wiring* R134A

$ 242.87

Availability: 15 in stock
  • Model: coqd35-2010
  • Type: icebox conversion kit
  • Refund will be given as: Money Back
  • Country/Region of Manufacture: Canada
  • Return shipping will be paid by: Buyer
  • Condition: New
  • Item must be returned within: 30 Days
  • Brand: KingETC
  • MPN: coqd35-2010
  • All returns accepted: Returns Accepted

    Description

    KINGETC Brand Icebox conversion kit
    model COQD
    35-2010
    This is a Conversion kit Icebox to fridge for up to
    6.25 cuft (180L) and
    freezer 2.1
    cuft
    (60L).
    Low amperage draw! Made in Canada
    There no gas included or precharged. Professional installation recommended.
    No wiring included. Marine grade Ready-made wiring harness soon available.
    =====
    Specification :
    12-24Vdc compressor Model QDZH35G (equivalent to bd35f) CE certified
    compact condensing air-cooled unit 9"x11"x7"
    Electronic thermostat included with 2m probe(not shown)
    6 foot of conduit from unit to plate
    10"x20" evaporator plate with spacers
    insulation and tape included
    =====
    Notes:
    Wiring :  1/4 quick terminals and crimper required
    10 gauge and a 15 amps for 12v (7.5amps for 24v) fuse for power input, 18 gauge wire for the rest.
    Here simplified installation instructions
    =====
    Gas not precharged, Refrigeration knowledge and tools required.
    Installation Procedure is
    similar
    to a mini-split.
    Screw  condensing unit in a vented area and Evaporator in icebox with spacers(leave a space between evap and wall)
    Route Evaportator piping to condensing unit and tighten flare
    fittings, Secure with clamps and insulate copper pipe.
    Tighthen fittings with 2 wrench, only the nut have to turn. avoid to twist the pipe
    Pressure check system for leaks with nitrogen at 50psi (higher will deform evaporator)
    Follow wiring
    schematic
    to connect compressor, fan and thermostat
    Pull vaccum for about down to at least 500 micron (vacuuming time not significant, proper gauge needed)
    Fill around 4 oz of R134a refrigerant into the well vacuumed system, Leave Manifold and Refrigerant bottle attached to system to add refrigerant later.
    Start compressor, let system run for 5-10 mins , check pressures (Manifold gauges) and temperatures (Infrared thermometer) during that time.
    If ,On the Low pressure side, Pressure fall under 0-3 psi when compressor running , add more refrigerant.
    Refer to R-134A Temp-pressure chart to make sure you get superheat and subcooling, that will ensure proper refrigerant charge.
    Stop compressor, Remove Manifold and Put Back both access  valve caps.
    =====
    I always carefully pack items with care to avoid damage during shipping.
    If item is undeliverable because of buyer's wrong, refused, unclaimed or incomplete address. Buyer pays return shipping cost to Seller (Both Original Shipping AND RETURN SHIPPING).
    Buyer is responsible for his import charges and fees if occurs.
    Feel free to contact me for any questions!
    Thanks