-40%
Automatic Timing & Controls ATC Groen 376A100Q50RX 111891 Totalizing Counter NOS
$ 145.19
- Description
- Size Guide
Description
Automatic Timing & Controls ATC Groen 376A100Q50RX 111891 Totalizing Counter NOS!!******************************************* FREE SHIPPING!! ***************************************
New Old Stock (NOS). These are new never installed or used counters. We have 2 units available, one with a box and 1 without a box.
Choose at checkout using the drop down list whether you want one with or without a box, both are new, never used.
See below and our photographs for additional technical information. Comes with paperwork as shown.
376A-100-Q50-RX is a counter with scaling - single preset relay output 120vac 50/60hz.
This listing is for ONE (1)
Automatic Timing & Controls ATC Groen 376A100Q50RX 111891 Totalizing Counter. Choose at checkout using the drop down list whether you want one with or without a box, both are new, never used.
Thanks for looking!!
From the manufacturer:
FEATURES
• 10 kHz Counting Frequency
• Single Preset, Dual Preset, Batch Counting Modes
• Interval Counting Mode with Separate Start
• Count with Inhibit Mode
• Internal Totalizing Counter
• Prescaler 0.00001 to 9.99999
• 6 Decimal Point Positions
• High Intensity Blue V-F Display
• 6 Digit Count Display
• Easy English Language Operator Prompts
• 72mm2 Panel - Dust, Water Tight
• 4 Snap-Action Keys
• Plug-in Housing (Quick Replacement)
• Easy DIP Switch Set-up
• Reset Key on Panel and External Resets
• Sinking, Sourcing, TTL Inputs
• Single, Bidirectional, and Quadrature (X1, X2, X4)
Counting
• Relay or Transistor Outputs
• Outputs Latched, Timed, or Off at Presets
• Regulated 12 VDC Aux. Power Supply
COUNTING MODES
The 376A is available as a Single Preset or a Dual Preset Counter. The Dual Preset Counter can be set as a Batch Counter. Both the Single Preset and the Dual Preset versions have an internal Totalizing Counter which will accumulate counts over numerous cycles. The 376A can be set up for Interval Counting Mode using a separate Start Signal, and can also be set up for Count with Inhibit Mode.
INPUTS/OUTPUTS
Two count inputs are available with the 376A. These inputs can be set to count Uni-and Bi-directionally. They can also be set to accept Quadrature inputs and can multiply the quadrature signals X1, X2 and X4. Input 2 also operates as the Start input in Interval Mode and as the inhibit input in Count with Inhibit Mode. These two inputs can be set to accept Current Sinking or Sourcing signals, and there is a High/Low Threshold (Bias) setting allowing the input of TTL level signals. Two types of outputs are available. The Relay outputs are rated for 10 A at 250 VAC and 30 VDC. The NPN Transistor outputs are current sinking and are rated for 100 mA at 30 VDC. These outputs are field replaceable. Each output can be set to either Latch ON, Remain ON for a Time Delay, or turn OFF at a Preset.
SCALE FACTOR
A Prescale value can be set which allows the operator to view and set counts using real units of measure. The Prescale value is a multiplier which is applied to the count inputs to determine the display and preset values. The Prescale value can be set from 0.00001 to 9.99999. The 376A also allows setting of the decimal point position in any of 6 positions.
RESETTING THE COUNTER
The Counter can be reset using the Reset key on the panel or by using the external Reset Inputs. There are three current sinking external inputs. Each one is dedicated to resetting the Process, Batch and Totalizing Counters. In addition, the 376A can be set to either retain its count or reset upon power failure.
OPERATOR PANEL AND HOUSING
The 376A operator panel is dust and water tight and measures a compact 72 mm2 . The panel features a high intensity blue vacuum fluorescent display. The display uses 8 digits for its English language operator prompts and 6 digits to display the count value. For operator use, there are 4 snap action keys which allow the operator to easily view Process Count, Batch Count, Totalizer Count, Presets, Scale Factor, Output Settings and Decimal Point position. The 376A can be set to lock out various displays from the operator. One key is dedicated to Resetting the Counter. This key can also be locked out